spectrmax 190. Products : SpectraMax M2/M2e reader, SpectraMax M5/M5e reader, Gemini XPS reader, FlexStation II (Obsolete), Gemini EM reader, FlexStation 3 reader. spectrmax 190

 
 Products : SpectraMax M2/M2e reader, SpectraMax M5/M5e reader, Gemini XPS reader, FlexStation II (Obsolete), Gemini EM reader, FlexStation 3 readerspectrmax 190 SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A

7 ± 0. spr SpectraMax iD3 SpectraTest ABS2 v1. Temperature control and shaking come as standard. 0 out of 5 $ 2,499 $ 1,999. SoftMax® Pro Software for Windows 10 and 11 is designed to provide the simplicity, flexibility and power required for advanced data analysis. Viewing this answer requires an authorized account. Flavonoid Compositions Analysis . With optimized reagents and the industry-leading data acquisition and analysis tool SoftMax® Pro 7 Software, the SpectraMax iD3 allows you to customize your workflow to. The data are shown in optical density (O. The SpectraMax 340PC 384 and SpectraMax Plus 384 read both 96-and 384-well microplates. Offer Ends In: 9 Days 19: 59: 40. SpectraMax 190 Register or Sign In. The SpectraMax 190 reader is the tool for DNA analysis. In addition, the SpectraMax iD5SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. The Molecular Devices SpectraMAX absorbance microplate readers mimic a dual beam spectrophotometer with a patented multichannel optical design. Database contains 2 Molecular Devices SpectraMax 190 Manuals (available for free online viewing or downloading in PDF): Operator's manual, Operation &. #730. The absorbance was determined at 510 nm using a SpectrMax 190 plate reader (Molecular Devices, CA, USA). The 1/absorptivity value for double stranded DNA at 260 nm is commonly assumed to be \~50 µg/mL for a 1-cm pathlength3,4. SpectraMax® ABS Plus, SpectraMax® 190* and VersaMax™* Microplate Readers. Certified SpectraMax ® M5 e-HTRF Readers The SpectraMax M5 e reader has the same perfor mance specifications as the M5 but is certified for use with Cisbio Bioassays HTRF (Homogeneous Time-Resolved Fluorescence) technology. a SpectraMax 190 spectrophotometer (Molecular Devices, LLC, Sunnyvale, CA). SpectraMax 190 Absorbance Microplate Reader from Molecular Devices LLC. 16 ‏$ $ ‎ 36,002 . SoftMax® Pro Software User Guide — 0112-0140 Rev. Molecular Dynamics Phosphorimager Model 425F + details. Step 3. Step 4. ®The SpectraMax Vertical 1000 uses only the highest-efficacy ams-Osram LEDs with efficiencies up to 4. With optimized reagents and the industry-leading data acquisition and analysis tool SoftMax® Pro 7 Software, the SpectraMax iD3 allows you to customize your workflow to. The SpectraMax® Gemini™ EM Microplate Spectrofluorometer from Molecular Devices® provides a flexible environment to determine the optimal excitation and emission settings for most fluorescent intensity assays. The standard curve was made using iron (II) sulphate solution (40–0. Glow-type luminescence provides an extended signal time window enabling batch processing of plates in screening assays;The SpectraMax® Gemini™ XPS Microplate Spectrofluorometer from Molecular Devices® provides a flexible environment to determine the optimal excitation and emission settings for most fluorescent intensity assays. The SpectraMax 340PC 384 and SpectraMax Plus 384 read both 96-and 384-well microplates. The SpectraMax® 190 Absorbance Microplate Reader is the ideal equipment for many life science applications including DNA analysis. The SpectraMax i3x reader has variable bandwidth for fluorescence and luminescence, and you are able to choose either 9nm or 15 nm for excitation and either 15 nm or 25 nm for emission. SpectraMax 190 Absorbance Microplate Readerwith laptop and softwareEnables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the UV-visible wavelength range, with the only temperature-independent method of pathlength correction. The following steps provide a quick reminder of the basic operating proce- Overview dures required to read a microplate using the SPECTRAmax 190. Unit Cables SpectraMax 190 User’s Manual and SoftMax Pro USB data loggers EBI 300 TE and EBI 300 TH Logger is user-programmable via free online configuration SpectraMax® 190 absorbance plate reader enables dataSpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. Perkin Elmer 1420 Victor 3V + details. No accessories are needed and SoftMax® Pro. 303 unable to cal dark current. IMI detection was conducted using the Eurofins Imidacloprid ELISA kit (Eurofins Abraxis, Warminster, PA, USA) following the manufacturer’s instructions for extraction and quantification of IMI residues in leaf tissue and using a spectrophotometer (SpectraMax 190, Molecular Devices, San Jose, CA, USA). How do I do this? Note: Check the Applies to section at the bottom of the page to make this is the. g. The drawing shows a standard microplate of 15 mm height covered with a lid. , Sunnyvale, CA). The change in absorbance was followed on either a Spectrmax 190 or Spectrmax Gemini XS plate reader (Molecular Devices Corp. , call 1-800-635-5577. $4,500. Wavelength Accuracy: < ± 2. The multichannel design for 96-well microplates uses separate sample and reference beams for each. Contains one microplate adapter, five 24-well low volume slides, five 64-well low volume bottom slides, and five of each cover slide (2 µL and 4 µL) 0200-6267. The SpectraMax Glo Steady-Luc Reporter Assay Kit is designed for optimal performance on microplate readers with high throughput enabled by both the microplate format and assay signal stability. Theseinstrumentsmeasuretheopticaldensity(OD)ofsamplesatselected wavelengthsinasinglereadmode. If no values are present, the water constant values are missing from the NVRAM. Both readers feature an 8-channel read head for fast reads and a subset feature, the temperature independent PathCheck sensor that. Description 1. The contents of the wells in a microplate can be mixed automatically by shaking before each read cycle, which makes it possible to perform kinetic analysis of solid- Contact Us Phone: +1-800-635-5577 Web: Email: info@moldev. The cell viability was normalised to the control group. The SpectraMax 340PC 384 and SpectraMax Plus 384 read both 96-and 384-well microplates. For colony-forming assays, stable Caki-1 and 796-O anti-miR-155/TCL6-OE cells and their respective control cells were plated at a low density onto 10-cm dishes (1,000. Perkin Elmer HTS 7000 Bio Assay ReaderExplore how the SpectraMax i3 Multi-Mode Platform provides an unlimited breadth of application possibilities, and how it can evolve with your future needs. When the correct COM port is selected, the. 00 +$350. Prior to the reading of each plate, the microplate reader was “blanked” with a. (2012). The contents of the wells in a microplate can be mixed automatically by shaking before each read cycle, which makes it possible to perform kinetic analysis of solid-SpectraMax M Series Multi-Mode Microplate Readers 7 The SpectraDrop Micro-Volume Microplate offers the ability to use as little as 2µL samples with 24- or 64-well plates. Perkin Elmer HTS 7000 Bio Assay ReaderMolecular Devices Spectramax 190 Plate Reader used. The SpectraTest® ABS1 Absorbance Validation Plate** enables you to qualify the performance of the system by . Home > Search Results > Danaher Inc > spectramax 190 microplate reader. Molecular Devices technical support is available by phone and e-mail. . The SpectraMax 190 Reader is the tool for DNA analysis. SPECTRAmax 190 Microplate Spectrophotometer Operator™s Manual 1-3 Introduction General Overview The SPECTRAmaxŽ 190 microplate spectrophotometer provides rapid and sensitive measurements of a variety of analytes across a wide range of concentrations. System setup and calibration are controlled from within SoftMax ®The SpectraMax® 190 Absorbance Microplate Reader is the ideal device for many life science applications, including DNA analysis. 2. Not all manufacturers microplates are the same with regard to design, mate- rials, or conÞguration. 118 Gemini XPS Fluorescence Microplate Reader . Molecular Devices microplate spectrophotometer, mod SpectraMAX 190, s/n 02552, includes computer. 1) All parts of the SPECTRAmax 190 Microplate Spectrophotometer are warranted for a period of one (1) year from the original date of delivery. -Narrow bandwidths deliver increased measurement accuracy and linearity - Wavelength Range: 190 - 1000 nmSpectraMax 190: SpectraMax 340PC384: SpectraMax Plus384: VERSAmax: Vmax: Tecan: Sunrise: Trinean: DropSense96: AMBIENT TEMPERATURE STORAGE: Liconic: LPX 220 Hotel: LPX 440 Hotel: Thermo Fisher Scientific: Cytomat 10 Hotel: Cytomat 2 Hotel: Cytomat 24 Hotel: Cytomat 8 Linear Hotel: Cytomat 9 Hotel (MPH) BAR CODE. The final value was expressed as ng/g protein. The contents of the wells in a microplate can be mixed automatically by shaking before each read cycle, which makes it possible to perform kinetic analysis of solid- Tecan Infinite M200 PRO Plate Reader-Tecan Mono Absorbance, Tecan Luminescence, Tecan PMT Enhanced -used system- includes Tecan system dongle. In luminescence mode, if you are specifying a wavelength for the read, you can select an emission bandwidth of either 15 nm or 25 nm. For customers outside the U. 0 Micromoles per Joule, ensuring the highest light output using the least amount of electricity. Molecular Devices Spectramax GeminiXS Plate Reader GeminiXS SpectrMAX , used, nice, excellent condition- inquire for further details + details. Photometric Performance SpectraMax 190 Item Description. SpectraMax 190酶标仪适用于大多数生命科学研究工作,尤其是DNA分析。能够检测任何标准96孔或UV-透射96孔微孔板。内置单色器,连续波长范围为190-850nm,步进波长1nm。提供终点检测、动力学和光谱扫描三种测读模式。具有温控系统和微孔板震荡混. to View Figures. SpectraMax® M3, M4, M5, and M5e Multi-Mode Microplate Readers User Guide 0112-0115 F July 2010 M3-M5e_manual. Add to Cart. These filter wheels are used for a host of applications, including color CCD photography, fluorescence microscopy, and photometry. Software tools for regulatory compliance, such as FDA 21 CFR Part 11, are available through SoftMax Pro GxP Software. The SpectraMax 340PC 384 and SpectraMax Plus 384 read both 96-and 384-well microplates. TheSpectraMax®190MicroplateSpectrophotometer,SpectraMax®340PC384Microplate Spectrophotometer,andVersaMax™MicroplateSpectrophotometerproviderapidandsensitive measurementsofavarietyofanalytesacrossawiderangeofconcentrations. We have 1 Molecular Devices SpectraMax 190 manual available for free PDF download: User Manual . ®The SpectraMax 190 Microplate Reader's optical system is built around a monochromator, allowing the selection of up to six wavelengths at a time for absorbance detection in the UV-Vis wavelength range (190 nm - 850 nm). The plate reader optics are tunable for absorbance, fluorescence intensity, fluorescence polarization, and time resolved fluorescence assays (TRF). No additional manuals are available. 009-QG. Service parts for these models are not being produced and are no longer in stock. for every assay. The crystal violet OD, which indicates the concentration of viable cells in the biofilms, was determined with a spectrophotometer (SpectraMax 190) at 570 nm. The Solution Speaking about how OligoMaker uses the SpectraMax 190, Karl Ross-Petersen explains, "We use the SpectraMax 190 as an important step in testing the DNA/RNA. Customer Satisfaction is our number one goal All lab equipment in stock already tested and ships in 1-3 daysreader (SpectraMax 190, Molecular Devices, USA). The absorbance of the reaction mixture was recorded at 593 nm (SpectraMax 190, Molecular devices) after 5 min. The Spectramax 190 absorbance microplate reader utilizes a patented multichannel optical design to simulate a dual beam spectrophotometer to help eliminate errors through the usage of a dual fiber optic exposure. VersaMax, SpectraMax 340PC384, 190, Plus 384 Microplate Readers User Guide Electromagnetic Compatibility Regulatory for Canada (ICES/NMB-001:2006) This ISM device complies with Canadian ICES-001. The drawer will open. SOFTmax PRO. Additional models are available. The optical system of the SpectraMax 190 Microplate Reader is built around a monochromator, which allows for selection of up to six wavelengths at a time for absorbance detection in the UV-visible wavelength range (190 nm - 850 nm). . The contents of the wells in a microplate can be mixed automatically by shaking before each read cycle, which makes it possible to perform kinetic analysis of solid-The change in absorbance was followed on either a Spectrmax 190 or Spectrmax Gemini XS plate reader (Molecular Devices Corp. All readings were taken in clear, polystyrene 96-shallow-well, flat-bottom plates. The patented multichannel optical design of the SpectraMax® 190 Absorbance Microplate Reader mimics a dual beam spectrophotometer, measures each sample in the plate. . The reaction was terminated by the addition of 50 μL of 2 mol/L H 2 SO 4 as the color changed, and the absorbance at 490 nm was analyzed using a SpectraMax 190 Microplate Reader (Molecular. #3635 or Greiner cat. For a higher degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader systems with all leading partner robots. 2 nm 光度量范围 0-4. For very concentrated samples, use a minimum volumeSpectraMax® 190. 5 - 2. Next, the supernatant was discarded, 120 μL of DMSO was added to each well, and the plate was shaken for 10 min in the dark to sufficiently dissolve the formazan crystals. to 500 nm) spectroscopy (SpectrMAX 190; Molecular. The plates were then read on a SpectraMax 190 reader (Molecular Devices) at 450 nm. Perkin Elmer HTS 7000 Bio Assay ReaderSpectraMax Plus or SpectraMax 190 and SoftMax Pro Software automatically: •Make A 260 and A 280 measurements •Measure the optical pathlength of each sample with the PathCheck sensor •Normalize the absorbance values to a 1 cm pathlength •Calculate concentrations •Make specialized calculations (e. 2 nm. Product Specs; Item SpectraMax 190 Absorbance Microplate Reader; Company Molecular Devices LLC; This product is no longer available on Biocompare. The SpectraMax 340PC 384 and SpectraMax Plus 384 read both 96-and 384-well microplates. Offer Ends In: 38 Days 16: 07: 54. The SpectraMax® 190 UV-Vis Microplate Spectrophotometer from Molecular Devices is ideal for life science applications, especially DNA analysis. Perkin Elmer HTS 7000 Bio Assay ReaderFigure 1. Dispose of filter, and replace with new filter. Molecular Devices Spectramax 190 Plate Reader used. . Exceptional performance SoftMax® Pro Software for Windows 10 and 11 is designed to provide the simplicity, flexibility and power required for advanced data analysis. Perkin Elmer 1420 Victor 3V + details. 1. Accurate quantitation The optical design of the SpectraMax 340PC384 reader truly mimics a dual. Lower limits of detection for ATP determined using the ATPlite . . Exceptional performancePreconfigured protocols and custom assay workflows simplify microplate data acquisition and analysis. Gemini XPS and EM Microplate Readers with dual monochromator fluorometers provide a flexible environment to determine the optimal excitation and emission settings for fluorescence intensity assays. Lower limits of detection for ATP determined using the ATPlite . Molecular Devices Spectramax GeminiXS Plate Reader GeminiXS SpectrMAX , used, nice, excellent condition- inquire for further details + details. Prepare your iD series instrument for shipment. • If SpectraMax can not communicate with a specific device, it will display a window showing which device and allow for the user to modify the communications settings or. Each sample has a discrete sample beam and reference beam so that each well is measured directly. SpectraMax i3x reader measures absorbance, fluorescence, & luminescence with user-upgradeable application including western blot imaging, AlphaScreen, fast kinetics along with injectors plus additional detection modes. For a higher degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader systems with all leading partner robots. 314 low lamp level warning. The SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. Fluorescence Microplate Reader Comparison Chart. Spleen Cell Proliferation. {"general":{"total":5,"offset":0,"limit":5,"data":[{"key":"label","path":"path","name":"Name","identifier":"Identifier","wavelength-ranges":"Wavelength ranges. iD5. A four‐parameter logistic function was used to fit the curve and determine unknown concentrations with the software. HTRF is a proprietary time-resolved fluoresce nce technology that overcomesThe VersaMax and SpectraMax 190 read 96-well microplates. Molecular Devices SpectraMax 190 Temperature range: 4°C above ambient to 45°C Digital controller and display Sold as-is The Molecular Devices SpectraMax 190 can be used to quantify DNA and perform endpoint, kinetic, and spectral scanning analyses. Time style: am/pm AM/PM 24-hour. Order Now. The bacterial pathogen associated with citrus huanglongbing (HLB) resides in the phloem of affected trees. HBV extracellular DNA and core-associated DNA. With optimized reagents and the industry-leading dataSpectramax M Series, supplied by Danaher Inc, used in various techniques. Absorption was measured at 450 nm 24 h after premix added using SpectraMax 190 (Molecular Devices, LLC, Sunnyvale, CA, USA) to produce a cell. These robust readers have been placed in labs from Antarctica to the. 사용이 편리하고 견고한 생명과학 연구, 신약 개발, 개발, Bioassay용 assay. . Overview. The contents of the wells in a microplate can be mixed automatically by shaking before each read cycle, which makes it possible to perform kinetic analysis of solid-The SpectraMax® iD3 Multi-Mode Microplate Reader is the cornerstone of a complete laboratory solution to help you expand the boundaries of your research capabilities. Description 1. Biotek PowerWave XS Microplate Reader BioTek Synergy HTX Microplate Reader - Absorbance Only BioTek ELx808 Ultra Microplate Reader - Absorbance OnlyThe SpectraMax® Quant™ dsDNA Assay Kits are designed for fluorescence-based dsDNA quantitation across a broad range of concentrations. 190 Gorge Road West has a Walk Score of 82 out of 100. Molecular Devices Spectramax 190 Plate Reader used. D 1 1. Contact AnytimeLabTrader SpectraMax 190 Absorbance Microplate Reader with laptop and software Enables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the UV-visible wavelength range, with the only temperature-independent method of pathlength correction. Also review the Maintenance and Troubleshooting chapter of the user guide for your model plate reader. See More Information. Molecular Dynamics Phosphorimager Model 425F + details. The SpectraMax ABS readers use a grating monochromator to select the exact wavelength needed . 00 . A SOFTMAX® PRO SOFTWARE Version 5 for Mac® and Windows® User Guide Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 The VersaMax and SpectraMax 190 read 96-well microplates. 2) If you wish to regulate the temperature inside the microplate reading cham-. Thermo Electron Corporation Nepheloskan Ascent / Type-750 96-Well Microplate Reader/Analyzer. For aqueous solutions, our patented* PathCheck® sensor technology senses the depth of the liquid in each microplate well, and normalizes the absorbance value to a 1-cm pathlength. . Examples: fiPress carefully to engage,fl fiDo not press down. 0112-0126B 8 Chapter1:Introduction TheSpectraMax®340PC384,SpectraMax®190,andVersaMax™microplate. 2 or higher, standard edition only, no GxP) VersaMax™ Microplate Reader (Serial numbers begining with BNxxxxx and BNRxxxxx are supported) SpectraMax® 190 Absorbance Microplate Reader (Serial numbers. Also, the coefficient of drug interaction (CDI) was calculated according to the formula CDI = AB/(AxB), where AB is the ratio of the treatment combination to the control and A or B is the. TheSpectraMax®190MicroplateSpectrophotometer,SpectraMax®340PC384Microplate Spectrophotometer,andVersaMax™MicroplateSpectrophotometerproviderapidandsensitive. Add to cart. used. As per Volza’s India Import data, Spectramax import shipments in India stood at 365, imported by 145 India Importers from 28 Suppliers. The information is below the horizontal line. testing optical specifications that are critical to achieve . Compatible automation solutions for SpectraMax Readers. Perkin Elmer HTS 7000 Bio Assay ReaderSpectraMax 190 Absorbance Microplate Reader. The SpectraMax 190 Microplate Reader from Molecular Devices is ideal for UV-Vis life science applications, especially DNA analysis. The ABS reader ranges from 340-850 nm in wavelength and the ABS Plus reader ranges from 190-1000 nm, which is equivalent to having 510 or 810 free filters, respectively. The Gemini XPS Reader has dual monochromators that allow users to utilize new and novel dyes without purchasing expensive filter sets. Spectramax Plus 384 Plate Reader. Check: In the data table create two new columns and add the following formulas: !Pathchecklm900. It may be named "Pothos". For very concentrated samples, use aMolecular Devices Spectramax 190 Plate Reader used. Molecular Devices Spectramax GeminiXS Plate Reader GeminiXS SpectrMAX , used, nice, excellent condition- inquire for further details + details. Fresh porcine aortic valve cusps were supplied by St. . Temperature control and shaking come as standard. The absorbances were measured at 450 nm and 630 nm on a SpectraMax 190 microplate reader (Molecular Devices) or an SH-1200Lab microplate reader (Corona Electric). T&Cs & Important Info. Perkin Elmer 1420 Victor 3V + details. The SpectraMax® 190 Microplate Reader from Molecular Devices is ideal for UV-Vis life science applications, especially DNA analysis. Description Control Panel Cuvette Chamber Back Panel Microplate Drawer The Control Panel TEMP on/off TEMP Figure 1. S. $2,350. It measures the optical density (OD) of samples in 96-wellThe absorbance was measured at 450 nm with a spectrophotometer (Spectramax 190, Molecular Devices Corp. ATP standard curves read on SpectraMax microplate readers. US. The iron contents were monitored at 562 nm using a microplate spectrophotometer (SPECTRAmax 190, Molecular Devices Corporation, USA). Spectramax Plus 384 Spectramax 190 Spectramax 340PC384 Versamax Microplate Spectrophotometers; A Fluorescence Correlation Spectrometer for Measurements in. Narrow bandwidths deliver increased measurement accuracy and linearity over the widest range of assays, including. (volume is not critical because water does not absorb light appreciably between 190 and 900 nm) and read the plate. SPECTRAmax 340PC Microplate Spectrophotometer Operator’s Manual 1-3 Introduction General Overview The SPECTRAmax ® 340PC incorporates a holographic grating monochromator which allows you to specify a precise wavelength, from 340 nm to 850 nm, for the absorbance maximum of your sample. Moonrise and moonset. NOTE: Limited support and literature is available for the SpectraMax 250 due to the senescence of the product. Our Price: $6,995. Pre-owned. 38 Dimension® EXL™ with LM Air Filter Monthly Maintenance. The patented multichannel optical design. Generate more data points without the need to dilute. Molecular Devices Spectramax 190 Plate Reader used. Where is the instrument serial number located? The serial number is on. Keywords: spectramax i3 multi-mode platform, spectramax i3, spectramax i3 system, scanlater western blot system, spectramax minimax imaging cytometer, softmax pro software,. SpectraMax® 190 absorbance plate reader enables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the UV-visible wavelength range, with the only temperature-independent method of pathlength correction. The SpectraMax 340PC 384 and SpectraMax Plus 384 read both 96-and 384-well microplates. The ABS reader ranges from 340–850 nm in wavelength and the ABS Plus reader ranges from 190–1000 nm, which is equivalent to having 510 or 810 free filters, respectively. The 293T cells were seeded into 6-well plates, using 330,000 cells. Microplate Readers. Concentration curves were run in triplicate and IC 50 values were calculated by following the 4-parameter logistic curve fitting equation. See the installation guide or user guide. . The SpectraMax® 190 UV-Vis Microplate Spectrophotometer from Molecular Devices is ideal. Wavelength Selection . 1) This. Gemini™. 1step assay with SpectraMax microplate readers. ) gap between the rear of the instrument and the wall. The SpectraMax 340PC 384 and SpectraMax Plus 384 read both 96-and 384-well microplates. SpectraMax 190 (Serial number starting with N) SpectraMax 250 SpectraMax 340 (Serial number starting with M) SpectraMax 340PC (Serial number. Equinoxes & Solstices. SOFTmax PRO makes it possible to. For more information, please visit us at would like to show you a description here but the site won’t allow us. When. 2. Category 2 and 3 microplate readers use gradient heating as well. Therefore, the measurement wavelength of the malachite green assay is not. It provides ready-to-run protocols, analysis algorithms, and 21 different curve fit options. Molecular Devices Spectramax 190 Plate Reader used. Sep 19, 2023 11am PT Date Format. In the blank group, tyrosinase was not added and the phosphate buffer was used to make up the volume. 7°C and the bottom to 36. • SpectraMax® 190 (Serial#-NNR-xxxxx) •ersaMax™ (Serial#-BNR-xxxxx) V • AquaMax® Microplate Washer. Molecular Dynamics Phosphorimager Model 425F + details. This location is in Saanich. Molecular Devices Spectramax 190 Absorbance Microplate Reader. The SpectraMax® 190 spectrophotometer is ideal for most life science applications, especially DNA analysis. The SpectraMax® 190 Absorbance Microplate Reader is the ideal equipment for many life science applications including DNA analysis. 119. The analysis was performed in triplicate and the results were expressed as mg gallic acid equivalent per g of extract (mg GAE/g). ZERO BIAS - scores, article reviews, protocol conditions and more. Theseinstruments TheSpectraMax®340PC384,SpectraMax®190,andVersaMax™microplate spectrophotometersproviderapidandsensitivemeasurementsofavarietyofanalytes acrossawiderangeofconcentrations. Near bottom. Step 2. Each sample has a discrete sample beam and reference. SpectraMax 250 User. Molecular Devices technical support. The protein contents of the samples were determined with the BCA Protein Assay Kit. . Molecular Devices SpectraMax 190 Microplate Reader. The SpectraMax ABS/ABS Plus Microplate Readers provide fast absorbance detection without the use of filters with monochromator-based wavelength selection for visible and. Perkin Elmer HTS 7000 Bio Assay ReaderLow-volume, high-throughput DNA and protein detection on the SpectraMax ABS Plus Microplate Reader. . ®The cell pellets were lysed with 200 mmol/L NaOH, and the iron content was determined using the ferrozine assay. Compounds were tested for inhibition of 3CL pro following a similar protocol with several small modifications. The narrow bandwidth provides greater measurement accuracy and linearity over the widest assay range, including DNA. Perkin Elmer HTS 7000 Bio Assay ReaderScanLater Western Blot Detection Cartridge. This location is Very Walkable so most errands can be accomplished on foot. ®HI Wendy, I dont have a lot of expertise but I'd just suggest you to check that the filter wheel isn't touching the metal chassis. SpectraMax iD3 reader. SPECTRAmax 190 Microplate Spectrophotometer Operator™s Manual 1-3 Introduction General Overview The SPECTRAmaxŽ 190 microplate spectrophotometer provides rapid and sensitive measurements of a variety of analytes across a wide range of concentrations. SoftMax® Pro Software User Guide — 0112-0140 Rev. In the control group, the flavonoid solution was. . After treatment with paramylon or lipopolysaccharide for 24 h, 10 μL of cell counting kit reagents was added to the cells. TheSpectraMax®340PC384,SpectraMax®190,andVersaMax™microplate spectrophotometersproviderapidandsensitivemeasurementsofavarietyofanalytes. SPECTRAmax PLUS 384 Microplate Spectrophotometer Operator’s Manual vii Conventions Used in this Manual The names of keys that appear on the SPECTRAmax PLUS 384 control panel are shown in boxed Helvetica type. UV Qualification, using NIST traceable standards, is now available for SpectraMax 190, Plus 384 and the M Series (M2/M3/M4/M5/M5e) Parameters that are checked during the UV Qualification are: Wavelength accuracy. 0 nm increments . Perkin Elmer 1420 Victor 3V + details. Temperature control and shaking come as standard. 0 nm * Wavelength Repeatability ± 0. Gemini XPS & EM readers measure fluorescence on a variety of sample formats from 6- to 384-well. The widespread abundance of the vector in Florida, the Asian citrus psyllid (Diaphorina citri), and the location of the pathogen in the tree vascular tissue limits the efficacy of foliar-applied therapies. The protein concentration was quantified using Bradford reagent (Sigma–Aldrich, Shanghai, China). 02 at 750 nm using a spectrophotometer (SpectraMax®190; Molecular Devices, San Jose, CA, United States). Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. The multi-channel design truly mimics a dual-beam spectrophotometer. The ABS reader ranges from 340–850 nm in wavelength and the ABS Plus reader ranges from 190–1000 nm, which is equivalent to having 510 or 810 free filters, respectively. The SpectraMax 190 reader is the tool for DNA analysis. This version is compatible with the following instruments: SpectraMax® Mini Multi-Mode Microplate Reader (software version 7. 3 Figures from 612 Publications Promega. SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. Información para pedidos: Includes current version of SoftMax Pro Software. 1: SpectraMax Plus 384 components. SpectraMax® M2/M2e user guide a multi-detection microplate reader with two-mode cuvette port SpectraMax M2e user guide cover 1 1 4/21/06 9:53:28 AM. Example: [Drawer]. United States. (b) Fluorescence responses of probe HADP and control compounds 2–4 (each 5 µM) towards human heparanase (HPA) (1 µg) in 40 mM NaOAc buffer (pH 5. The plate. Wavelength precision. For very concentrated samples, use a minimumThe SpectraMax Plus 384 Microplate Reader for absorbance measurements from 190 to 1000 nm quickly for samples in test tubes, cuvettes, and 96- or 384-well microplates. 315 can't find zero order. UV-Star ® 96W Microplate, well working volume 25-370 μL; total well volume 392 μL. The instrument is designed to regulate the temperature of the plate chamber from 5°C above ambient to 45°C. SPECTRAmax 190 Microplate Spectrophotometer Operator™s Manual 1-3 Introduction General Overview The SPECTRAmaxŽ 190 microplate spectrophotometer provides rapid and sensitive measurements of a variety of analytes across a wide range of concentrations. Description 1. 00. United States. SPECTRAmax® 190. On LabX buyers can find. polynomial 2nd analysis from the protein standards. item 3 Molecular Devices SpectraMax 190 Microplate Spectrophotometer Molecular Devices SpectraMax 190 Microplate Spectrophotometer . spr SpectraMax iD5 SpectraTest ABS2 v1. SpectraMax 190: Located in the back of lab 302 . It features a dual-monochromator system, a large dynamic range, and a high-throughput capability. Expanded dynamic range. 2. The VersaMax and SpectraMax 190 read 96-well microplates. , Tokyo, Japan) was added to each well every 24 h. 0 out of 5 $ 9,995 $ 9,495. Wavelength Bandwidth. 1*, Win 10*. For planktonic growth, 120 μ L of the bacterial cultures from each well was transferred to well plate and the a new 96-6 optical density at 595 nm was measured. 1 32-bit Win 7, 64-bit Win 7, Win 8*, Win 8. com Check our website for a current listing of worldwide distributors The VersaMax and SpectraMax 190 read 96-well microplates. Rigging/Removals Loading, Rigging, and Freight are at buyers expense. The control panel consists of a 2-x-20-character LCD and eleven pressure-sensitive membrane keys that can be used to control some functions of the instrument. The value for 1000 should be higher than the value for 900. SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus384 SpectraMax 190 SpectraMax 340PC384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. Thermal Chamber Filter (disposable) • Pull the filter cover and filter off of their plastic frame. Efects of luciferase concentration, luciferin concentration, ATP concentration, pH, temperature, and reaction time on the. The temperature in the plate chamber is ambient and isothermal. The SpectraMax® absorbance spectrophotometers and plate readers provide the versatility and convenience for a wide range of assays such as ELISAs, nucleic acid and protein quantitation, and microbial growth. The PathCheck sensor can extend the instrument linearity by a factor of three or more. ATP standard curves read on SpectraMax microplate readers. Service Contracts, Preventative Maintenance and Performance.